MODEL S12 |
12 CHANNEL, 24 BIT, 100MPPS SCALER
FEATURES:
12 CHANNELS, 24 BITS, IN A SINGLE WIDTH CAMAC MODULE
- DC-100MPPS COUNTING RATES
- INTERRUPT CAPABILITY WITH IMPENDING OVERFLOW INDICATION
- INDEPENDENT TEST MODE BY INHIBITING SIGNAL INPUTS
- CASCADE CHANNELS FOR 48 BIT CAPACITY
APPLICATIONS:
TOTALIZING TO 100MPPS
JOERGER ENTERPRISES, INC. MODEL S12 is a 12 channel, 100MPPS scaler
packaged in a single width CAMAC module. The module uses standard ICs which
eliminates the stocking of special hybrids and reduces the possibility of module
obsolescence. The inputs are D.C. coupled and can accept signals as narrow as 5nsec. at
rates of 100MPPS. High speed CLEAR and INHIBIT are provided from the front panel and in
addition, the module can be gated and reset from the dataway. A LAM structure is provided
that, if enabled, will indicate an impending overflow of any channel. An interrupt
flip-flop is triggered when a channel reaches a half full condition. A test function is
also available that will inject signals into all the channels simultaneously. Testing can
be performed in the presence of input signals by inhibiting the modules inputs. For
applications requiring a capacity of greater than 24 bits the channels can be cascaded to
provide 48 bit capacity. In this mode the overflow flip-flop would still be set when half
the capacity has been used, in this case when bit 48 is first set.
SPECIFICATIONS: (for each channel)
| PULSE REPETITION RATE |
DC to 100MPPS |
| INPUT IMPEDANCE |
50 ohms ± 5% DC coupled |
| PULSE WIDTH |
5nsec. minimum |
| PROTECTION |
± 5 volt transients |
| IMPEDANCE |
50 ohms ± 5% DC coupled |
CAMAC COMMANDS
| COMMAND |
Q |
FUNCTION |
| 0x |
1 |
Reads data from channel x** onto read lines 1-24 |
| 2x |
1 |
Reads data from channel x** onto read lines and resets all
scaler channels with A11 (S2) |
| 80-11 |
* |
Test "Look at Me" flip-flop, Q=1 if set.
Independent of LAM disable |
| 90-11 |
|
Clears all channels at S2 |
| 240-11 |
|
Disables LAM response on L line |
| 250-11 |
|
Increments all scalers |
| 260-11 |
|
Enables LAM response |
| C (S2) |
|
Resets all channels and overflow flip-flop |
Z (S2) or
POWER UP |
|
Resets all channels, overflow flip-flop and disables LAM
response |
| I |
|
Inhibits all scalers |
| L |
|
An interrupt is generated if any scaler has reached half
scale and the module is enabled. L is disabled when the module is addressed on its N line |
| X |
|
An X response is generated for all valid commands |
| Q |
|
A Q is generated in response to F0, F2 and F8 if the modules
interrupt flip-flop has been set |
** NOTE x=0-11 FOR CHANNELS 0-11 RESPECTIVELY
| CONNECTORS: |
LEMO RA00250 or equivalent |
| TEMPERATURE RANGE: |
0° C to 50°
C |
| POWER REQUIREMENTS: |
+6v, 950ma |
| SIZE: |
#1 CAMAC module |
JOERGER ENTERPRISES, INC 166 Laurel Road, East Northport, NY 11731
USA
| 1-631-757-6200 |
(Fax 1-631-757-6201) |
www.joergerinc.com |
[HOME] [CAMAC] [VME]
[NIM]
|