MODEL CS

 

24 BIT OPTICALLY ISOLATED
INPUT REGISTER

 

FEATURES:

  • 24 OPTICALLY ISOLATED INPUTS PROTECTED TO 1500 VOLTS D.C.
  • 5, 12, 24, 48V D.C. OR 120V A.C. INPUT LEVELS
  • INPUT FILTERING
  • 24 BIT REGISTER
  • VISUAL DISPLAY OF DATA INPUTS

 

APPLICATIONS:

  • 24 BIT INDIVIDUALLY OPTICALLY ISOLATED INPUTS
  • EACH INPUT IS FILTERED, AND HAS A THRESHOLD OF HALF ITS INPUT LEVEL
  • IT'S ISOLATION VOLTAGE OF 1500VDC MAKES IT IDEAL FOR MONITORING PRESSURE AND MECHANICAL SWITCHES, RELAYS, ALARMS AND LEVEL DETECTORS

 

JOERGER ENTERPRISES, INC. MODEL CS can accept up to 24 two wire inputs and is packaged in a single width CAMAC module. Each input is optically isolated up to 1500VDC and has been designed to sense inputs by monitoring the presence or absence of external voltage. In this way it can monitor such things as limit switches, relay contacts or pressure switches. A version is also available to accept TTL level signals thus providing an inexpensive optically isolated input register. In addition to TTL signals, the unit can accept four other standard input levels. These are 12V D.C., 24V D.C., 48V D.C. and 120V A.C. Other ranges can be made available and the factory should be consulted if a different input is required. The input threshold is approximately half the input signal to be sensed. The input circuit draws between 5 and 10ma to help clean the contacts. Filtering is provided on each input to eliminate contact bounce. The standard time constant is 100msec. although 10, 50, and 200msec. time constants are available. Because of the asynchronous nature of the inputs, a register is provided. This register tracks the inputs continuously and when the module is read out onto the dataway, the register is disabled insuring stable data during readout. A logic "1" is read out if the contact is closed, indicated by the presence of a voltage. A front panel display is also provided to visually indicate the state of the inputs.

 

SPECIFICATIONS: (for each channel)

INPUTS (EACH IS A FLOATING 2 WIRE PAIR)

MODEL CS-5 5 Volts D.C.
MODEL CS-12 12 Volts D.C.
MODEL CS-24 24 Volts D.C.
MODEL CS-48 48 Volts D.C.
MODEL CS-120 120 Volts A.C.
INPUT THRESHOLD Approximately 1/2 the level to be sensed
INPUT ISOLATION 2500 volt surge, 1500 volt D.C.
INPUT CURRENT 5 to 10ma

CAMAC COMMANDS:

COMMAND

Q

FUNCTION
00

1

Reads out data onto read lines R1-R24. Logic "1" = contact closed, voltage present.
115

1

Reads out module identity in BCD OV.101.T
Where V equals: 0000
0001
0010
0100
1000
120V A.C.
12V D.C.
24V D.C.
48V D.C.
5V D.C.
Where T equals: 0000
0001
0010
0100
100msec. Time Constant Std.
10msec. Time Constant Std.
50msec Time Constant Std.
200msec.Time Constant Std
X All valid commands generate an X=1
CONNECTORS: AMP 552118-1
Mating half AMP 229974-1 or equivalent
TEMPERATURE RANGE: 0° C to 50° C
INDICATORS: "N"
"DATA"
Module addressed
The 24 inputs are visually displayed on 24 front panel LED displays
POWER REQUIREMENTS: +6v, 450ma (all LED’s on)
-6v, 10ma
SIZE: #1 CAMAC module