Joerger Logo

MODEL ADC32A

 

 

32 CHANNEL, SCANNING ADC
AND DATA LOGGER

 

FEATURES:

  • HIGH SPEED ADC, 10m SEC PER CHANNEL
  • 12 BIT RESOLUTION WITH SAMPLE AND HOLD INPUT
  • INSTRUMENTATION AMPLIFIER, PROGRAMMABLE GAIN PER CHANNEL
  • 32 DIFFERENTIAL INPUT CHANNELS
  • ACTIVE CHANNELS PROGRAMMABLY SELECTED
  • CONTINUOUS, BURST OR MULTIBURST MODES PROGRAMMABLY SET
  • ACTIVE MEMORY SIZE PROGRAMMABLE UP TO 2MEGA WORDS

 

The JOERGER ENTERPRISES, INC. MODEL ADC32A is a scanning 32 channel differential analog input module capable of operating as an ADC or data logger. To satisfy a wide range of applications the module is completely programmable. To match the module to the application, the number of active channels can be programmed along with the active memory size. This allows only the channels of interest to be scanned and stored. The module can be set for continuous scan or for one of two triggered modes of operation; single burst or multiburst For data logging up to two megawords of memory is available. The standard input is bipolar, ± 10 volts, as an option it can be set for unipolar operation. To better match the input to the ADC range, a programmable instrumentation amplifier is provided with gain selections of 1, 2, 4, or 8. The gains can either be set for each individual channel or one gain can be used for the complete module. To simplify data readout, each channel is read out along with the gain of the amplifier for that channel. Data can be read out directly or in a block mode with offset binary coding. Direct readout is accomplished using F0 and F1 with the appropriate subaddress. This can be done while the unit is active so that data can be read on the fly. The block readout is available by using F2. To insure good noise rejection and channel isolation, the analog section is carefully grounded and the power lines well filtered. Input filtering on the analog inputs is available as an option.

SPECIFICATIONS:

CHANNELS 32 Differential Inputs
ACTIVE CHANNELS 1, 2, 4, 8, 16, 32 Channels, Programmably Set
GAIN SELECTION 1, 2, 4, 8 Individually Set Per Channel
INPUT RANGE Bipolar ± 10V Standard, Unipolar +10V Optional
RESOLUTION 12 Bits
ACCURACY ± .024%
APERTURE JITTER 150psec.
INPUT IMPEDANCE 100M Ohms Minimum
CONVERSION TIME 10m sec. Per Channel Maximum
ACTIVE MEMORY Selectively Set to 2M Words Maximum, 128K Standard
SCAN TRIGGER INPUT External Negative Going TTL
EXTERNAL CLOCK INPUT External Negative Going TTL

 

CAMAC COMMANDS:

0.Ai Reads data from Channels 1-16 on R1-12 and amplifier gain on R15, 16
1.Ai Reads Data from Channels 17-32 on R1-12 and amplifier gain on R15, 16
20 Reads the active memory in a block mode, data on R1-12, gain on R15, 16
30 Reads module identity
40 Reads module status; active channels, active memory size, operating mode, module active, internal or external clock and common or individual channel
gain select
80 Tests LAM, Q=1 if LAM is set and enabled
90 Resets module to 32 channel scanning ADC, with 32 word memory, Common
Gain = 1, internal clock and continuous scan (ADC32 operating mode)
100 Resets LAM
160 Writes module status; sets number of active channels, size of active memory, operating mode, internal or external clock, activates single gain mode for all channels and sets gain
17.Ai Sets gain on Channels 1-16 with data on W1, 2
20.Ai Sets gain on Channels 17-32 with data on W1, 2
240 Disables LAM response
241 Disable trigger override, lam must be reset to accept trigger (only if enabled)
250 When in burst mode and not active, resets LAM FF and triggers scan.
251 Stops cycle, resets counter
260 Enables LAM response
261 Enable trigger override (trigger will clear LAM and start burst cycle)
270 Tests LAM, Q=1 if LAM is set
271 Tests module busy, Q=1 if module is in a triggered data acquisition cycle
X An X=1 for all valid commands
Q A Q=1 for F0, 1, 3, 4 and in response to F2, 8, 16, 17, 20, 25 and 27
L An L response is generated in the burst mode when the active memory has been filled, in multi-burst mode when the modules complete memory is full
Z Resets module (ADC32 Emulation)
Power Up Resets module (ADC32 Emulation)
INDICATORS: "N" Module is addressed
"ACTIVE" Module is in a data acquisition cycle
POWER REQUIREMENTS: +6v, 325ma; +24v, 20ma; -24v, 20ma
SIZE: Single width CAMAC module
CONNECTORS: DATA -DC37P; TRIGGER, CLOCK -LEMO RA00250
TEMPERATURE RANGE: 20° C to 50° C
OPTIONS: 1. Unipolar input range 0 to +10v
2. Memory capacity, 128K (standard), 2M
3. Input filters

 

JOERGER ENTERPRISES, INC 166 Laurel Road, East Northport, NY 11731 USA